Technical Tools

Battery & BMS

Lithium-ion Battery Pack

Series-parallel cells storing traction energy (48–72 V in 2W/3W).

Lithium-ion Battery Pack

Purpose

Series-parallel cells storing traction energy (48–72 V in 2W/3W).

Working principle

Lithium ions shuttle between anode and cathode during charge/discharge.

Technical specifications

Voltage51.2 V (16s LFP) / 60 V / 72 V
Capacity30–105 Ah
Ratings & standards: Refer to AIS-156 / AIS-038 and OEM service manual.

Step-by-step usage

  1. 1Apply safety: key OFF, LOTO, verify zero energy where required.
  2. 2Visually inspect connectors, wiring and mounting.
  3. 3Measure key values with the correct instrument.
  4. 4Compare with specification and record on job card.

EV practical example

16s LFP: full 58.4 V, empty ~44 V.

Related Technician Lab practical

Battery Diagnostic Station