Technical Tools

Electrical Measurement

Insulation Resistance Tester

Applies a high DC test voltage to measure insulation resistance in megaohms.

Insulation Resistance Tester

Purpose

Detects leakage between HV conductors and chassis in motors, cables and packs.

Working principle

Ohm's law at 250–1000 V: a tiny leakage current reveals resistance R = V / I.

Technical specifications

Test voltage50/100/250/500/1000 V
Range0.01 MΩ – 20 GΩ
Safety ratingCAT IV 600 V
Ratings & standards: IEC 61557-2; AIS-156 / ISO 6469-3 require ≥ 100 Ω/V (DC) isolation.

Step-by-step usage

  1. 1Inspect the instrument, leads and insulation for damage; confirm rating ≥ system voltage.
  2. 2De-energise, LOTO and verify zero voltage before testing.
  3. 3Connect between conductor and chassis; select 500 V and press TEST.
  4. 4Record the reading on the job card and compare with OEM specification.

EV practical example

Motor phase-to-frame should read well above 10 MΩ on a 72 V 3W motor.

Related Technician Lab practical

Motor & Controller Testing Station