Technical Tools
Electrical Measurement
Insulation Resistance Tester
Applies a high DC test voltage to measure insulation resistance in megaohms.

Purpose
Detects leakage between HV conductors and chassis in motors, cables and packs.
Working principle
Ohm's law at 250–1000 V: a tiny leakage current reveals resistance R = V / I.
Technical specifications
| Test voltage | 50/100/250/500/1000 V |
| Range | 0.01 MΩ – 20 GΩ |
| Safety rating | CAT IV 600 V |
Ratings & standards: IEC 61557-2; AIS-156 / ISO 6469-3 require ≥ 100 Ω/V (DC) isolation.
Step-by-step usage
- 1Inspect the instrument, leads and insulation for damage; confirm rating ≥ system voltage.
- 2De-energise, LOTO and verify zero voltage before testing.
- 3Connect between conductor and chassis; select 500 V and press TEST.
- 4Record the reading on the job card and compare with OEM specification.
EV practical example
Motor phase-to-frame should read well above 10 MΩ on a 72 V 3W motor.