Clamp Meter

Measures current through a conductor without breaking the circuit.

Clamp Meter

Purpose

Checks motor phase current, charging current and parasitic drain.

Working principle

A Hall-effect sensor in the jaw senses the magnetic field around the conductor (DC & AC).

Technical specifications

Range0–600 A DC/AC
Accuracy±2%
Jaw opening30 mm
Safety ratingCAT III 600 V
Ratings & standards: IEC 61010-2-032.

Step-by-step usage

  1. 1Inspect the instrument, leads and insulation for damage; confirm rating ≥ system voltage.
  2. 2Zero the meter (DC A) with jaws closed and empty.
  3. 3Clamp around ONE conductor only, centred in the jaw.
  4. 4Record the reading on the job card and compare with OEM specification.

EV practical example

A 60 V scooter charger at full rate shows ~5 A on the battery positive cable.

Related Technician Lab practical

Charging Diagnostic Station