Technical Tools
Diagnostics & Communication
EV Charger Testing Equipment
Adapters and analyzers that test charger output, earthing and protocol signals.

Purpose
Diagnoses 'not charging' complaints for portable and LEV chargers.
Working principle
Simulates vehicle states and measures output voltage, current and earth leakage.
Technical specifications
| Input | 230 V AC |
| Output test | 0–100 V DC, 0–20 A |
| RCD test | 30 mA |
Ratings & standards: IS 17017 (EV charging), LEVDC / Bharat standards.
Step-by-step usage
- 1Inspect the instrument, leads and insulation for damage; confirm rating ≥ system voltage.
- 2Verify socket earth and input voltage.
- 3Connect charger to the tester load; record CC/CV output.
- 4Record the reading on the job card and compare with OEM specification.
EV practical example
A 60 V LFP charger should reach 73 V CV and taper current near full.