Technical Tools
Battery Testing
Battery Cell Tester / Grader
Tests individual cells for voltage and internal resistance to match them.

Purpose
Essential for pack repair and reassembly with balanced cells.
Working principle
4-wire Kelvin measurement removes lead resistance error.
Technical specifications
| Voltage | 0–5 V per cell |
| IR resolution | 0.01 mΩ |
Ratings & standards: Match cells within ±10 mV and ±5% IR.
Step-by-step usage
- 1Inspect the instrument, leads and insulation for damage; confirm rating ≥ system voltage.
- 2Clean cell terminals.
- 3Measure each cell, then sort into grade bins.
- 4Record the reading on the job card and compare with OEM specification.
EV practical example
An 18650 at 3.20 V when the rest are 3.62 V is a weak cell to replace.