Technical Tools

Battery Testing

Battery Cell Tester / Grader

Tests individual cells for voltage and internal resistance to match them.

Battery Cell Tester / Grader

Purpose

Essential for pack repair and reassembly with balanced cells.

Working principle

4-wire Kelvin measurement removes lead resistance error.

Technical specifications

Voltage0–5 V per cell
IR resolution0.01 mΩ
Ratings & standards: Match cells within ±10 mV and ±5% IR.

Step-by-step usage

  1. 1Inspect the instrument, leads and insulation for damage; confirm rating ≥ system voltage.
  2. 2Clean cell terminals.
  3. 3Measure each cell, then sort into grade bins.
  4. 4Record the reading on the job card and compare with OEM specification.

EV practical example

An 18650 at 3.20 V when the rest are 3.62 V is a weak cell to replace.

Related Technician Lab practical