CAN Bus Analyzer
Captures and decodes CAN frames between BMS, controller, charger and cluster.

Purpose
Diagnoses communication loss, wrong termination and noisy networks.
Working principle
Reads differential voltage between CAN-H (≈3.5 V dominant) and CAN-L (≈1.5 V dominant).
Technical specifications
| Bit rate | 125/250/500 kbps |
| Interface | USB, isolated |
| Termination | 120 Ω switchable |
Ratings & standards: ISO 11898-2.
Step-by-step usage
- 1Inspect the instrument, leads and insulation for damage; confirm rating ≥ system voltage.
- 2Key OFF: measure ~60 Ω between CAN-H and CAN-L.
- 3Key ON: connect analyzer and log frames at the correct bit rate.
- 4Record the reading on the job card and compare with OEM specification.
EV practical example
Reading 120 Ω instead of 60 Ω means one terminating resistor is missing.