Technical Tools
Battery Testing
Battery Cycler
Charges and discharges cells/packs under programmed profiles to measure true capacity.

Purpose
Capacity verification after repair and warranty assessment.
Working principle
Coulomb counting of Ah delivered during CC/CV charge and CC discharge.
Technical specifications
| Voltage | 0–100 V |
| Current | 0–50 A |
| Channels | 1–8 |
Ratings & standards: IEC 62660-1 capacity test methods.
Step-by-step usage
- 1Inspect the instrument, leads and insulation for damage; confirm rating ≥ system voltage.
- 2Set chemistry limits (LFP 2.5–3.65 V/cell).
- 3Run a full charge-discharge cycle at 0.5C.
- 4Record the reading on the job card and compare with OEM specification.
EV practical example
A rated 30 Ah pack delivering 22 Ah has ~73% SoH.