Technical Tools
Battery Testing
Battery Analyzer
Measures pack voltage, internal resistance and estimates State of Health.

Purpose
Quickly grades lithium and lead-acid packs used in 2W/3W EVs.
Working principle
Injects a 1 kHz AC signal and measures the AC response to calculate internal resistance (IR).
Technical specifications
| Voltage | 0–100 V |
| IR range | 0.1 mΩ – 3 Ω |
| Accuracy | ±1% |
Ratings & standards: IEC 62660, IS 16893 (lithium cells for EVs).
Step-by-step usage
- 1Inspect the instrument, leads and insulation for damage; confirm rating ≥ system voltage.
- 2Select chemistry and nominal voltage.
- 3Kelvin-clip the main terminals and start the test.
- 4Record the reading on the job card and compare with OEM specification.
EV practical example
A 48 V 30 Ah LFP pack rising from 80 mΩ to 160 mΩ indicates ageing.